ZKL-1000 Industrial Switching Power Supply Module


Feature:
·Voltage input range: 180-264VAC
· Protection types: Short circuit / Over current / Over temperature
· Analog voltage control
· Main channel external on/off control
Applications:
·Industrial control or automation devices
·Laser-related machinery
·UV curing equipment
·Charging equipment
·Test and measurement instruments
·Aging test equipment
Description
ZKL-1000 is a 1KW single-output enclosed AC-DC/DC-DC power supply. The entire series features an input voltage range of 180-264VAC / 250-370VDC and delivers DC output that meets most industrial requirements. Each model is cooled by an internal speed-controlled fan and can operate at a temperature of up to 60℃. Built-in multiple functions such as adjustable output voltage and current, remote on/off control, and auxiliary power supply provide a variety of design flexibilities.
Standard parameters listed below; custom specifications are available.
Model | ZKL-1000-12 | ZKL-1000-24 | ZKL-1000-36 | ZKL-1000-48 | ZKL-1000-72 | ZKL-1000-96 | ZKL-1000-110 | ZKL-1000-150 | ZKL-1000-220 | |||||||||
OUTPUT | DC Voltage | 12V | 24V | 36V | 48V | 72V | 96V | 110V | 150V | 220V | ||||||||
Rated Current | 83.3A | 41.6A | 27.7A | 20.8A | 13.8A | 10.4A | 9A | 6.6A | 4.5A | |||||||||
Current Range | 0 - 83.3A | 0 - 41.6A | 0 - 27.7A | 0 - 20.8A | 0 - 13.8A | 0 - 10.4A | 0 - 9A | 0 - 6.6A | 0 - 4.5A | |||||||||
Rated Power | 1000W | |||||||||||||||||
Ripple | 200mV | 200mV | 260mV | 350mV | 500mV | 600mV | 850mV | 900mV | 1000mV | |||||||||
Optimal CC Range | 6 - 12V | 12 - 24V | 18 - 36V | 24 - 48V | 36 - 72V | 48 - 96V | 55 - 110V | 75 - 150V | 110 - 220V | |||||||||
Voltage Accuracy | ± 1.0% | |||||||||||||||||
Line Regulation | ± 1.0% | |||||||||||||||||
Load Regulation | ± 1.0% | |||||||||||||||||
Start-up& Rise Time | 1500mS,100mS/230VAC(满载) | |||||||||||||||||
INPUT | Voltage Range | 180 - 264VAC / 245 - 370VDC | ||||||||||||||||
Frequency Range | 45Hz - 65Hz | |||||||||||||||||
Efficiency | 85 % | 86 % | 87 % | 89 % | 90 % | 90 % | 90 % | 91 % | 91 % | |||||||||
AC Current | < 13A | |||||||||||||||||
Leakage Current | < 3.0mA / 240VAC | |||||||||||||||||
Protection | Short Circuit | Enters constant current mode | ||||||||||||||||
Over Temperature | Shuts down output, automatically recovers or restores after temperature drops | |||||||||||||||||
Function | Output Voltage Adjustment | 0 - 13.2V | 0 - 26.4V | 0 - 39.6V | 0 - 52.8V | 0 - 79.2V | 0 - 105.6V | 0 - 121V | 0 - 165V | 0 - 242V | ||||||||
Output Constant Current Adjustment | 0 - 83.3A | 0 - 41.6A | 0 - 27.7A | 0 - 20.8A | 0 - 13.8A | 0 - 10.4A | 0 - 9A | 0 - 6.6A | 0 - 4.5A | |||||||||
External Potentiometer | External potentiometer control (voltage, current) | |||||||||||||||||
Analog Voltage Control | 0 - 5V / 0 - 10V control (voltage, current) | |||||||||||||||||
Auxiliary Power Supply | 12V 0.5A | |||||||||||||||||
Remote Switch | Default on, high level off (3V-12V) | |||||||||||||||||
Environment | Operating Temperature | -20 - +45℃ | ||||||||||||||||
Work humidity | -20 - 90% RH No condensation | |||||||||||||||||
Storage Temperature& Humidity | -40 - +85℃, 10 - 95% RH, no condensation | |||||||||||||||||
Vibration Resistance | 10 - 500Hz, 2G, 10 minutes/cycle, 60 minutes each for X, Y, Z axes | |||||||||||||||||
Safety | Insulation Resistance | Input to Output: 100MΩ/500VDC/25℃/70%RH | ||||||||||||||||
Withstand Voltage | I/P-O/P :1.2KVAC I/P-FG:1.2KVAC O/P-FG:0.5KVAC | |||||||||||||||||
|
| |||||||||||||||||
|
| |||||||||||||||||
Others
| Dimensions | 237*130*65mm(L*W*H) | ||||||||||||||||
Net Weight | 1.88 KG | |||||||||||||||||
Remarks | 1. 1. All parameters are measured at 230VAC input voltage, rated load and 25℃ unless otherwise specified. 2. 2.Ripple and noise voltage are measured with a 20MHz bandwidth oscilloscope, a 12-inch twisted pair with a 0.1μF and 47μF capacitor at the end, under 20MHz bandwidth. 3. 3.Accuracy includes setting error, line regulation and load regulation. 4. 4.Derated output is required for low input voltage conditions, please refer to the static characteristic curve for details. 5. 5.Start-up time is measured under cold start; frequent on/off operations may increase the start-up time. 6. Static Characteristic Curve. | |||||||||||||||||
Static Characteristic Curve


Mounting Dimensions: